Use of the Apnea Monitor 使用窒息監(jiān)視器
SUPPLIES AND EQUIPMENT 用品
Apnea monitor with electrodes
Material to cleanse the infant's skin 電極窒息監(jiān)視器
嬰兒皮膚清潔用品
PROCEDURES 操作
1. Wash hands. 洗手
2. Gather equipment. 收集用具
3. Explain to caregivers what is to be done and why. 向護(hù)工說明操作程序及目的
4. Prepare the infant's skin by making sure it is clean and dry. 嬰兒皮膚準(zhǔn)備,確保皮膚清潔干燥
5. Apply the electrodes (either to the infant or to the electrode belt, depending on the type of monitor being used). 貼電極片(根據(jù)監(jiān)視器類型,將電極貼于嬰兒皮膚或貼于電極帶)
a. Place the electrode belt at the infant's nipple line. l 將電極帶置于嬰兒乳頭線
b. Skin electrodes are usually best placed between the infant's nipple and armpit and may be repositioned somewhat. l 皮膚電極通常置于嬰兒乳頭和腋窩間,也可以置于其他部位。
6. Insert lead wires. Insert the white lead wire on the right side. Insert the black wire on the left. 插入導(dǎo)聯(lián)線:白色導(dǎo)聯(lián)線插右側(cè);黑色導(dǎo)聯(lián)線插入左側(cè)。
7. Insert the corresponding lead wire into the cable, and insert the cable into the monitor. The cable is usually color coded to match the lead wires. 將相應(yīng)導(dǎo)聯(lián)線與電線相接,將電線插入監(jiān)視器。電線顏色通常與導(dǎo)聯(lián)線顏色相配。
8. Attach the belt to the infant. The belt should be snug but you should be able to insert two fingers under it. 電極帶固定于嬰兒身上。電極帶固定松緊度以能插入兩個手指為宜。
9. Make sure the monitor is plugged in, the cable is attached, and the alarms are properly set. 確保監(jiān)視器、電線和報警裝置連接設(shè)置正常。
10. Turn on the monitor. The indicator lights should be on as well. 打開監(jiān)視器。提示燈亮。
11. Settle the infant comfortably, or allow caregivers to hold and comfort their infant. 嬰兒體位舒適,或由護(hù)工懷抱并安慰嬰兒。
12. If the monitor alarm sounds: 如監(jiān)視器報警:
a. Check the infant immediately. 立即檢查嬰兒;
b. Check the infant's breathing and color. If the infant is pink but not breathing, wait until the 10th beep before starting stimulation. If the infant is not pink, begin stimulation immediately. Believe observations of the infant before relying on the monitor. 檢查嬰兒呼吸和膚色。如膚色粉紅但無呼吸,等警報器蜂鳴10下后再開始刺激。如嬰兒不是粉紅色,則立即開始刺激。操作時以觀察結(jié)果為準(zhǔn),監(jiān)視器顯示為參考。
13. Use this stimulation sequence: Gently touch the infant; flick the infant's heel; slap the infant's foot; rub the infant's back. (Note: Be certain to teach caregivers never to shake the infant). If the child does not respond, start cardiopulmonary resuscitation (CPR). After the problem resolves, the alarm will stop. 行連續(xù)刺激:輕觸嬰兒,指彈嬰兒腳跟,拍擊嬰兒足部,搓擦嬰兒背部(教導(dǎo)護(hù)工絕不能搖晃嬰兒)。如無反應(yīng),開始心肺復(fù)蘇。問題解決,告警停止。
14. Press the reset button to turn off the alarm indicator. 按復(fù)位鍵關(guān)閉告警指示器。
15. Document and report any alarms and nursing responses. Document the infant's condition. Always note alarm settings when starting and ending any contact with the infant and at least every hour in between. 記錄并報告警報及護(hù)理反應(yīng)。記錄嬰兒病情。在開始和結(jié)束與嬰兒接觸時應(yīng)始終注意警報器設(shè)置,每小時不少于一次。